GE RAB6 D 4d Probe Repair Motor Control Failures

Brand Name : GE

Model Number : RAB6--D

MOQ : 1

Price : Negotiable

Payment Terms : T/T,Western Union

Delivery Time : 1-5 work days

Packaging Details : Neutral Package

Category : Diagnostic medical device service

Description : repair motor

Service : motor problem

Warranty : 60 days after fixed

Condition : Original

Purpose : Diagnosis for ultrasound

Contact Now

Repair 3D/4D GE RAB6--D Motor/Diagnostic Medical Device Service

Motor control failures

If the array stops moving or gets stuck, the motor control function has failed and may need to be repaired or replaced.

Solution

Motor repair

GE RAB6 D 4d Probe Repair Motor Control Failures




Other hot GE models we can repair:

GE C1-5-D
GE C1-5-RS
GE 4C
GE 4C-RS
GE 4C-A
GE 4C-D
GE 4C-SC
GE E8C/E8C-RS
GE E8CS
GE RIC5-9-D
GE 3CRF-D
GE C1-6-D
GE RAB4-8-RS
GE RAB2-5-RS
GE 6S-RS
GE 12L-RS
GE 3SC-RS
GE L6-12-RS
GE 11L
GE 11L-D
GE 12L-RS
GE 8C
GE 3S
GE 3S-RS

Common ultrasound Probe Damage(Specialty 3D/4D Volume probes)

Common ultrasound probe damage Solutions
Lens cap damage Lens cap replacement
Fluid and oil leaks Lens cap replacement, oil reservoir repair and replacement
Cable cuts Cable patches, possible cable replacement
Inoperative steering Motor repair
Connector housing electrical damage Minor electrical repairs, pin module replacement
Weak or dead elements, dropouts in an image Array ball replacement, oil reservoir repair and replacement

Warnings and cautions of ultrasonic probe

The ultrasonic probe is a valuable device. It must be careful in the process of use. Avoid dropping, impact, or abrasion to transducers.

When installing or removing the probe, first switch off the power and then operate it carefully.

Avoid rapid and extreme temperature changes, as well as lengthy exposure to direct sunlight or a strong ultraviolet light source.

Do not use sharp objects to penetrate the acoustic lens.Once the acoustic lens is damaged, the coupling gel is easy to enter the interior of the probe and damage the piezoelectric element.

Do not soak transducer in any liquid above the recommended level as stated in the user manual for your system, please operate according to the manufacturer's instructions, otherwise it will lead to circuit failure or even burn out.

Do not disinfect at high temperature, because the probe is equipped with piezoelectric ceramics, high temperature will weaken the effect.

Before use, carefully check whether the housing and cable are damaged, so as to prevent the probe from high voltage injury.

After the probe is used, the residual coupling gel on the probe must be wiped clean to prevent rats or other animals from gnawing the lens.

Storage for Transport of ultrasonic transducer

  • Make sure that the transducer is clean and disinfected before placing it in the case to avoid contaminating the foam that lines the carrying case.
  • Place the transducer in the case carefully to prevent kinking of the cable.
  • Before closing the lid, make sure no part of the transducer is protruding from the case.
  • Wrap the case in plastic material containing sealed-air pockets (such as Bubble Wrap material), and pack the wrapped case in a cardboard carton.



Product Tags:

GE RAB6 D 4d Probe Re

      

Motor Control Failures 4d Probe Repair

      
Quality GE RAB6 D 4d Probe Repair Motor Control Failures wholesale

GE RAB6 D 4d Probe Repair Motor Control Failures Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou Rongtao Medical Tech LTD.
*Subject:
*Message:
Characters Remaining: (0/3000)